Meters and More

Meters for Utility & Industrial Power Testing

AEMC BR07
  • Rotary Switch Selector
  • Stop Position To Prevent Accidental Switching From 10 To 0
  • Seven Decades: 1 To 10MΩ
  • Max Current: 0.1mA
  • Male Ground (Earth) Terminal With Safety Jack
  • Outputs On Ø 4mm Safety Terminals
  • Ground Jumper Lead EN 61010-2-031, 150V Cat. II Pollution Degree 2
  • Accuracy 1%
Data Sheet
Emerson TREX
  • Enables HART or Fieldbus module communications
  • Configure and test valves inline
  • Configure and test instruments inline
  • Touchscreen display is easy to use with bulky work gloves
Data Sheet
EXTECH 380400
  • 1 To 11,111,110 Ohm, 1 Ohm Per Step
  • Wattage : 1W
  • Slide Switches That Allow The User To Simply Add Or Subtract For Desired Value
  • With Seven Decades Of Resistance
  • ABS Plastic Housing Case, Rugged Components
Data Sheet
FLUKE 1587
  • Dynamic Output Stabilization
  • Multi-Functionality
  • Expandability
  • Convenient And Efficient Pass-Through Technique.
    Relay Testing
  • Current Transformer Testing
  • Recloser And Sectionalizers
  • Switchgear Testing
  • Heat Runs
Data Sheet
FLUKE 190-204
  • 200 MHz Bandwidth Model
  • Deep Memory: 10,000 Samples Per Channel Waveform Capture So You Can Zoom In On The Details
  • Dedicated 5000 Count Digital Multimeter
  • Connect-And-View Continuous Auto-Trigger, Single Shot, Pulse Width, And Video Triggering
  • ScopeRecord Roll Mode, Capture Waveform Sample Data For Up To 48 Hours
  • TrendPlot, Trend Measurement Readings For Up To 22 Days
  • Advanced Automatic Measurements, Power (Vpwm, VA, W, PF) And Time (MAs, V/S, W/S)
  • IP-51 Rated For Dust And Drip Proof To Withstand Harsh Environments
Data Sheet
FLUKE 289
  • True RMS Datalogging Multimeter
  • AC Bandwidth Specified To 100 KHz
  • Min/Max/Avg And Peak Capture
  • Low Impedance Voltage Function
  • AC/DC Voltage Range: 50.000 MV To 1000.0 V
  • AC/DC Current Range: 500.00 ΜA To 10.000 A
  • Resistance Range: 500.00 Ω To 500.0 MΩ
  • Capacitance Range: 1.000 NF To 100 MF
  • Frequency Range: 99.999 Hz To 999.99 KHz
Data Sheet
FLUKE 376
  • True RMS Datalogging Multimeter
  • AC Bandwidth Specified To 100 KHz
  • Min/Max/Avg And Peak Capture
  • Low Impedance Voltage Function
  • AC/DC Voltage Range: 50.000 MV To 1000.0 V
  • AC/DC Current Range: 500.00 ΜA To 10.000 A
  • Resistance Range: 500.00 Ω To 500.0 MΩ
  • Capacitance Range: 1.000 NF To 100 MF
  • Frequency Range: 99.999 Hz To 999.99 KHz
Data Sheet
FLUKE 725
  • Calibration Of Both Temperature And Pressure Transmitters
  • Measure/Source/Simulate MA Loop Parameters
  • Measure And Source MA, Volts DC, Frequency, And Resistance
  • Built-In 24 V Loop Power Supply
  • Store And Recall Frequently Used Calibration Set Ups
Data Sheet
FLUKE 789
  • Compact Digital Multimeter And MA Loop Calibrator Solution
  • Full-Featured MA Loop Calibrator With Built-In 24v Loop Power
  • Quickly And Easily Troubleshoot Every Part Of A Control Loop
  • Large, Bright Dual-Measurement Display
Data Sheet
FLUKE 9040
  • Indication Of Field Rotation In Three-Phase Networks
  • Fast, Clear Indication
  • Clear, LCD Screen
  • Fused Test Leads
  • Three Crocodile Clips And Three Test Probes
Data Sheet
FLUKE 9144
  • Lightweight, Portable, And Fast
  • Built-In Two-Channel Readout For PRT, RTD, Thermocouple, 4-20 MA Current
  • True Reference Thermometry With Accuracy To ±0.01 °C
  • On-Board Automation And Documentation
  • Metrology Performance In Accuracy, Stability, Uniformity, And Loading
Data Sheet
Fluke 805 FC
  • Reliable, repeatable, accurate device for checking bearings and overall vibration
  • Features innovative sensor design that minimizes measurement variations caused by device angle or contact pressure
  • Provides consistent data quality at both low and high frequency ranges
  • Offers four-level severity scale to assess urgency of problems and bearing condition
  • Measures overall vibration (10 Hz to 1,000 Hz) for acceleration, velocity, and displacement units of measurement for a wide variety of machines
  • Provides Crest Factor+ technology for reliable bearing assessment using direct sensor tip measurements between 4,000 Hz and 20,000 Hz
  • Compares vibration levels with ISO-10816 severity scales and stores results to the Fluke Connect Cloud
  • Features colored lighting system (green, red) and on-screen comments to indicate how much pressure needs to be applied to take measurements
Data Sheet
Powerent DB-650
  • Temperature range can be from 50℃ to 660℃
  • Touch screen operation, one-key heating, automatic temperature control is convenient to us
  • Multi-stage temperature control, rapid temperature rise, zero overshoot, fast and stable
Data Sheet
SOLMETRIC PVA-1500
  • Measures And Displays I-V And P-V Curves And Key Parameter Values
  • Advance Dbuilt-In PV Models Provide Immediate PV Performance Checking
  • Accurately Measures High-Efficiency Modules And Strings.
  • Database Of More Than 70,000 Modules, With Automatic Updates
Data Sheet
VAISALA DM70
  • Get Data Quickly – Fast Response Time Enhanced By Sensor Purge Function Ensures Quick And Accurate Data
  • Reliable Measurements – The Sensor Withstands Condensation And Fully Recovers From Getting Wet
  • Intuitive User Interface – Easy-To-Use User Interface, A Clear Graphical LCD Display, And Data-Logging Capability
  • Vaisala DRYCAP® Sensor With Unique Auto-Calibration Function
  • Data Can Be Logged And Transferred To A PC Via MI70 Link Software
  • Multi-Probe Operation: Relative Humidity And CO2 Probes Can Also Be Connected To The MI70 Indicator
Data Sheet
Arbiter 928A
  • 0.1 % Accuracy
  • Power and Energy
  • Flicker per IEC 61000-4-15
  • Harmonics I, V to 50th, THD
  • Phase Angle I-I, V-V, I-V
  • Waveform Display
Data Sheet
CRYSTAL XP2I DIGITAL PRESSURE GAUGE
  • Available to 15 000 psi
  • Marine grade enclosure resists corrosion
  • Accuracy not affected from -10 to 50°C
  • Replaces 5 or more digital test gauges
  • Fast pressure safety valve (PSV) mode
  • Easy to use
Data Sheet
Emerson TREX
  • Enables HART or Fieldbus module communications
  • Configure and test valves inline
  • Configure and test instruments inline
  • Touch screen display is easy to use with bulky work gloves
Data Sheet
FLUKE 190-204 ScopeMeter
  • 200 MHz bandwidth model
  • Deep memory: 10,000 samples per channel waveform capture so you can zoom in on the details
  • Dedicated 5000 Count digital multimeter
  • Connect-and-View continuous auto-trigger, single shot, pulse width, and video triggering
  • ScopeRecord roll mode, capture waveform sample data for up to 48 hours
  • TrendPlot, trend measurement readings for up to 22 days
  • Advanced automatic measurements, power (Vpwm, VA, W, PF) and time (mAs, V/s, w/s)
  • IP-51 rated for dust and drip proof to withstand harsh environments
Data Sheet
FLUKE 289
  • True RMS Datalogging Multimeter
  • AC bandwidth specified to 100 kHz
  • Min/Max/Avg and Peak capture
  • Low impedance voltage function
  • AC/DC voltage range: 50.000 mV to 1000.0 V
  • AC/DC current range: 500.00 µA to 10.000 A
  • Resistance range: 500.00 Ω to 500.0 MΩ
  • Capacitance range: 1.000 nF to 100 mF
  • Frequency range: 99.999 Hz to 999.99 kHz
Data Sheet
FLUKE 376
  • iFlex® Flexible Current Probe expands the measurement range to 2500 A AC
  • CAT IV 600 V, CAT III 1000 V
  • True RMS AC voltage and current for accurate measurements on non-linear signals
  • Min, max, average and Inrush recording to capture variations automatically
  • Integrated low pass filter and state-of-the-art signal processing allows for use in noisy electrical environments while providing stable reading
Data Sheet
Fluke 725 Multifunction Process Calibrator
  • Calibration of both temperature and pressure transmitters
  • Measure/source/simulate mA loop parameters
  • Measure and source mA, Volts DC, frequency, and resistance
  • Built-in 24 V loop power supply
  • Store and recall frequently used calibration set ups
Data Sheet
FLUKE 789
  • Compact digital multimeter and mA loop calibrator solution
  • Full-featured mA loop calibrator with built-in 24v Loop Power
  • Quickly and easily troubleshoot every part of a control loop
  • Large, bright dual-measurement display
Data Sheet
FLUKE 1587
  • Dynamic output stabilization
  • Multi-functionality
  • Expandability
  • Convenient and efficient pass-through technique.
    Relay testing
  • Current Transformer testing
  • Recloser and Sectionalizers
  • Switchgear Testing
  • Heat runs
  • Ground Grid testing
Data Sheet
FLUKE 9040
  • Indication of field rotation in three-phase networks
  • Fast, clear indication
  • Clear, LCD screen
  • Fused test leads
  • Three crocodile clips and three test probes
Data Sheet
FLUKE 9144 Metrology Well
  • Lightweight, portable, and fast
  • Built-in two-channel readout for PRT, RTD, thermocouple, 4-20 mA current
  • True reference thermometry with accuracy to ±0.01 °C
  • On-board automation and documentation
  • Metrology performance in accuracy, stability, uniformity, and loading
Data Sheet
Multi Gas Clip Simple Plus
  • 3 year run time - 3 year life!
  • No charging ever! No calibration necessary!
  • Large, easy to read screen
  • Simple One Button Operation
  • Works in oxygen enriched and oxygen deficient environments
  • Continuous 1 second data logging
  • LEL sensor is immune to H2S & silicone poison
Data Sheet
Honeywell TL-2055 Test Lamp
  • Suitable for virtually all UV, IR and UV/IR flame detectors • 0,3-0,6 meter (1-2 ft) test range for generic UV, IR and UV/IR flame detectors
  • Up to 5 meters (16 ft) Test Range for Fire Sentry FS18X, FS20X en FS24X flame detectors Light weight: only 2.1 kg (4.5 lbs)
Data Sheet
Lutron RBOX-488
  • 1 to 11,111,110 ohm, 1 ohm per step
  • Wattage : 1W
  • Slide switches that allow the user to simply add or subtract for desired value
  • With seven decades of resistance
  • ABS plastic housing case, rugged components
Data Sheet
ProComSol HM-USB-ISO-BP USB HART Modem
  • 1500 Vdc Opto Isolation between HART and USB circuits
  • USB 1.1 and 2.0 compatible
  • Integral standard USB type A connector
  • Integral heavy duty HART Minigrabber connectors
  • Self powered, no external power supply or batteries needed
  • 48” (1.2m) cable length
  • Rugged ABS plastic enclosure with rubber boot
Data Sheet
RAlston Nitropak
  • Proprietary pressure-balanced fine adjustment piston allows for extremely precise, finger-tip control of pressure at 0.03 psi (2 mbar) or 3000 psi (210 bar) or any range in between
  • Easily refillable nitrogen cylinder holds enough gas for multiple calibrations
  • Designed to meet US Department of Transportation (DOT) and Canadian Transport Canada (TC) standards
Data Sheet
Solmetric PVA-1500
  • Measures and displays I-V and P-V curves and key parameter values
  • Advance dbuilt-in PV models provide immediate PV performance checking
  • Accurately measures high-efficiency modules and strings.
  • Database of more than 70,000 modules, with automatic updates
Data Sheet
Vaisala DM70
  • Get data quickly – Fast response time enhanced by sensor purge function ensures quick and accurate data
  • Reliable measurements – The sensor withstands condensation and fully recovers from getting wet
  • Intuitive user interface – Easy-to-use user interface, a clear graphical LCD display, and data-logging capability
  • Vaisala DRYCAP® sensor with unique auto-calibration function
  • Data can be logged and transferred to a PC via MI70 Link software
  • Multi-probe operation: relative humidity and CO2 probes can also be connected to the MI70 indicator
Data Sheet
VIATOR USB HART Interface Mactek
  • Fully HART compliant for communication with any HART instrument and error-free slave testing
  • Easy installation (Software Drive included)
  • Draws power from USB port and needs no external power supply
  • Rugged ABS plastic case gives you industrial-grade reliability in a small package
Data Sheet